Lutronic Clarity II Laser Hair Removal

Brand :

$13.400,00

Condition : Used

Year : 2024

 

The Lutronic Clarity II is an advanced dual-wavelength aesthetic laser platform engineered for dermatology clinics, medical spas, and aesthetic practitioners. Combining high-powered 755 nm Alexandrite and 1064 nm Nd:YAG wavelengths in a single versatile system, it safely and effectively treats all skin types (Fitzpatrick I–VI) with exceptional speed and precision.

Lutronic Clarity II Laser Hair Removal

Equipped with intelligent IntelliTrak™ technology and real-time skin temperature sensing, the Lutronic Clarity II ensures uniform energy delivery, consistent clinical outcomes, and enhanced patient safety across high-volume practices.

Key Advantages for Clinical Practice Lutronic Clarity II:

  • True Dual-Wavelength Versatility: Seamlessly switch between 755 nm Alexandrite (for lighter skin types and fine hair) and 1064 nm Nd:YAG (for darker skin tones and deeper vascular lesions).

  • IntelliTrak™ Rapid Roller Technology: Automatically adjusts pulse repetition rates based on handpiece gliding speed, delivering consistent overlapping coverage for fast, full-body hair removal.

  • Real-Time Temperature Sensing: Integrated skin temperature monitoring provides instant visual and audio feedback to prevent overheating and maximize patient safety.

  • Cryogen Cooling System (ICD): Built-in intelligent cooling delivers targeted bursts of cryogen before and after each laser pulse, minimizing discomfort without the mess of contact gels.

  • Wide Range of Spot Sizes: Supports multiple ergonomic spot sizes (from 2 mm up to 24 mm) for customized precision on both small facial veins and large body areas.

Technical Specifications Lutronic Clarity II:

  • Manufacturer: LUTRONIC

  • Product Name: Lutronic Clarity II

  • Equipment Classification: Medical / Aesthetic Laser Device

  • Laser Type: Dual-Wavelength Solid-State Laser (Alexandrite & Nd:YAG)

  • Wavelengths: 755 nm and 1064 nm

  • Spot Sizes: Up to 24 mm (adjustable depending on handpiece configuration)

  • Cooling System: Built-in Intelligent Cooling Device (ICD) / Cryogen Spray

  • Clinical Indications: Permanent hair reduction (all skin types), epidermal & dermal pigmented lesions, vascular lesions (telangiectasia, leg veins, rosacea), and skin rejuvenation

Ideal For:

Dermatology clinics, aesthetic medical centers, plastic surgery practices, and high-volume medspas seeking a fast, reliable, multi-application laser platform.

FAQ Lutronic Clarity II:

Prospective Patients

    • Is the treatment painful?
      Most patients experience only a mild warming sensation or a light rubber-band snap in sensitive areas. The device features an integrated Intelligent Cryogen Cooling (ICD™) spray or air-cooling system that immediately cools the skin before, during, and after each laser pulse to maximize comfort.
    • Is it safe for darker or tan skin tones?
      Yes, it is designed to be safe for all skin types and tones (Fitzpatrick types I through VI). The 1064 nm Nd:YAG wavelength penetrates deeper to target the follicle or vessel while bypassing surface skin pigment, significantly reducing the risk of burns or hyperpigmentation.
    • How many sessions are needed to see results?
      The exact number depends on the skin condition and treatment goals. For permanent hair reduction, patients typically require 4 to 6 sessions spaced 4–6 weeks apart to effectively target hair follicles during their active growth phase.
    • How long does a session take, and is there any downtime?
      A single session is very fast, typically lasting 5 to 20 minutes depending on the size of the treatment area. There is minimal to no downtime—the most common side effects are mild redness or slight swelling that subsides within a few hours, allowing patients to return to normal activities immediately.
    • What pre- and post-treatment care is required?
        • Before: Avoid sun exposure/tanning, waxing, plucking, and harsh exfoliants or retinoids prior to your appointment (shaving the area beforehand is recommended for hair removal).
        • After: Apply broad-spectrum sunscreen daily and avoid direct sun exposure, hot showers, saunas, or strenuous exercise for 24–48 hours.

Physicians & Clinic Owners

    • How does it differ from the previous generation (Clarity I) or similar competitors?
      Clarity II introduces IntelliTrak™ technology, which automatically adjusts the laser repetition rate to match the practitioner’s hand speed—preventing missed spots or excessive overlap—alongside Real-Time Temperature Sensing to continuously monitor skin temperature for added clinical safety. Official regional distribution and medical support are handled by authorized partners such as idsMED Aesthetics.
    • Does the device require consumables?
      Consumable requirements depend on the chosen cooling method. If a clinic utilizes the built-in cryogen cooling module (ICD™), cryogen canisters will need periodic replacement. However, the system is also compatible with external air-cooling devices (such as Zimmer Cryo), which eliminate the need for cryogen canisters.
    • How versatile is the device for maximizing Return on Investment (ROI)?
      By combining two wavelengths (755 nm and 1064 nm) with a wide range of spot sizes (2 mm to 25 mm) and pulse widths down to 1 ms, a single platform can treat a broad spectrum of indications—including high-speed hair removal, pigmented lesions, vascular lesions (spider veins/rosacea), and non-ablative skin rejuvenation.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.