NIDEK TONOREF III AUTOMATIC REFRACTOMETER FOR SALE!!

Nidek Tonoref III is 3rd generation Multi-Function Pretest Station with Combination of Non-Contact Pachymeter Tonometer also Auto Refractometer Keratometer.
$3,600.00
Qty:
The TONOREF III combines the functionality of an auto refractometer, auto keratometer, non contact tonometer and non-contact pachymeter into one device. Multiple measurements can be performed at one sitting, increasing patient comfort and maximizing clinical efficiency. The space saving design of the TONOREF III ensures effective use of office space.

Nidek Tonoref III performed with Objective measurement of accommodation and provided calculation function on the central corneal thickness. Tonoref III advantages and benefits:
  • High measurement accuracy
  • Accommodation measurement and opacity assessment
  • User-friendly design
  • Space saving with efficient upgrade
  • performed multiple measurements in one sitting
  • clinical efficiency Maximising
  • patient comfort improved

Automated calculation of corrected IOP
The TONOREF III provides the automated calculation function of the corrected IOP based on the central corneal thickness.

Accommodation measurement
Objective measurement of accommodation is performed with patient's focusing on a target which moves from distant to near.

Opacity assessment
The retroillumination image allows evaluation of media opacity.

Large pupil zone imaging method
The large pupil zone imaging method measures the central refraction and a large area refraction. The difference of the measurement allows assessment of the effect of pupil size such as a vision in dim light.

Double mire ring method
Keratometry measurements performed with the mire ring method reduce interference from the eyelids. The TONOREF III performs measurements at diameters of 3.3 mm and 2.5 mm. Comparison of the two values allows a better understanding of the cornea shape.

Patient-friendly air puff
Automatic Puff Control (APC). In subsequent measurements, the APC function performs the measurement with the minimum air pressure based on the previous measurement data.

Softer and quieter air puff
Gentle nozzle design. A gentle nozzle design reduces patient’s perception of physical pressure.

Features:
  • Combination of auto refractometer, auto keratometer, non contact tonometer and non contact pachymeter
  • High measurement accuracy
  • Clinically important functions ‐ accommodation measurement and opacity assessment
  • User-friendly design
  • Space saving design that is a comfortable and efficient upgrade to your practice

#Nidek #Ophthamology #OphthamologyEquipment
  • Availability: 10 In Stock
  • Model: NIDEK TONOREF III AUTOMATIC REFRACTOMETER
  • Brand: Nidek

Write Review

Note: Do not use HTML in the text.